NUP1301U

Ultra low capacitance ESD protection array


Ultra low capacitance ElectroStatic Discharge (ESD) protection array in a small SOT323 (SC-70) Surface-Mounted Device (SMD) plastic package designed to protect one signal line in rail-to-rail configuration from the damage caused by ESD and other transients.

Features and benefits

  • ESD protection of one signal line (rail-to-rail configuration)
  • Ultra low diode capacitance: Cd = 0.6 pF
  • ESD protection up to 30 kV
  • IEC 61000-4-2; level 4 (ESD)
  • IEC 61000-4-5 (surge); IPP = 11 A
  • AEC-Q101 qualified

Applications

  • Telecommunication networks
  • Video line protection
  • Microcontroller protection
  • I²C-bus protection
  • Antenna power supply
  • Analog audio
  • Class-D amplifier
All information on this product information page is subject to the subsequent disclaimers:

Parametrics of this product

Type numberPackage versionPackage nameSize (mm)Nr of protected linesConfigurationCd [typ] (pF)Cd [max] (pF)VRWM (V)VESD IEC61000-4-2 (kV)IRM [max] (µA)
NUP1301USOT323SC-702 x 1.25 x 0.951Unidirectional0.60.7580300.1

Documentation for this product

File nameTitleTypeFormatDate
NUP1301UUltra low capacitance ESD protection arrayData sheetpdf2011-01-28
NUP1301U_NXP_Product_QualityNUP1301U NXP Product QualityQuality documentpdf2014-04-22
NUP1301U_NXP_Product_ReliabilityNUP1301U NXP Product ReliabilityQuality documentpdf2014-07-16
NUP1301UNUP1301U SPICE modelSPICE modelprm2012-07-22
sot323_poplastic surface-mounted package; 3 leadsOutline drawingpdf2009-10-08
SOT323_135Tape reel SMD; standard product orientation 12NC ending 135Packingpdf2012-11-16
SOT323_115Tape reel SMD; standard product orientation 12NC ending 115Packingpdf2012-11-16
Reflow_Soldering_ProfileReflow Soldering ProfileReflow solderingpdf2013-09-30
sot323_fwFootprint for wave soldering SOT323Wave solderingpdf2010-07-13
sot323_frFootprint for reflow soldering SOT323Reflow solderingpdf2010-07-13

Technical support

Do you want to ask technical questions to an NXP expert?
Please select one of the following options:

Find answers to your design questions on this page. If available you can find information in our NXP Support Community or you can find NXP models, Demo boards and Design tools.

Models

TitleTypeDate
NUP1301U SPICE modelSPICE model2012-07-22

Frequently asked questions and Community discussions

The Frequently asked questions are answers provided by NXP technical experts. The discussions are between users of the Community, these can be NXP technical experts, but also other users.

Please wait. Loading data...


No items available, please go to the Community to engage in a new discussion.

Disclaimer All Community items are matched using search logic, so not all results may be equally relevant.
Any opinions, advice, statements or other information in the discussions posted or transmitted by any third party are the responsibility of the author of that message and not of NXP.

{"subtitle":"","category":[],"basictype":["NUP1301U"]}

How to search?

Already registered to MyNXP? or Register

Feedback

Restricted Document

You are accessing a password protected document.
Please choose an option below

Fill in your name, company and e-mail address and you will receive an e-mail with a username and password for this restricted document.

First name*

Last name*

Company*

E-mail*

Comments

Fields with an * are required

Print password request form:

Before we can grant you access to our confidential documents you are required to fill in, print and sign the password request form by which you comply with the NXP Non-disclosure agreement (NDA). Please email or fax the signed form to the email-address or fax-number specified on the form. After approval you will receive username and password via email. In case you already signed an NDA with NXP and already have username and password, you can skip this step.

Open document:

If you have received the username and password, you can open the document by clicking on the "open document" link. You will be prompted for username and password. After you fill in the username and password the download will start.

Forgot your password:

In case you forgot your password you can click on the "forgot your password" link to retrieve your password. Please complete the small form with your personal details and your request will be sent to NXP. You will receive an answer with your password shortly.

Request secure documentation

Fill in your name, company and e-mail address and you will receive an e-mail with a username and password for this secure document.

First name*

Last name*

Company*

E-mail*

Comments

Fields with an * are required

Datasheet confidential

Fill in your details and you will be contacted

First name*

Last name*

Company*

Country*

Telephone number*

E-mail*

Fields with an * are required

Your e-mail address will only be used to send the datasheet and will not be used for any other purposes.

No full datasheet available

Fill in your details to receive notification when the datasheet becomes available

First name*

Last name*

Company*

E-mail*

Fields with an * are required.

Your email address will only be used to send the datasheet and will not be used for any other purposes.