MOTOROLA

 

Semiconductor Products Sector

Issuing Division: BODY ELECT, OCCUPANT SAFETY (JD


PRODUCT AND PROCESS CHANGE NOTIFICATION

Generic Copy


24-JUN-2003


  
Subject:    MOTOROLA PRODUCT AND PROCESS CHANGE NOTIFICATION 8963
TITLE:

AMBIENT TEST ELIMINATION FOR MC9S12DX64


EFFECTIVE DATE:        25-Jul-2003


AFFECTED CHANGE CATEGORIES

·  TEST PROCESS



AFFECTED PRODUCT DIVISIONS

·  WIRELESS COMMUNICATIONS DIV (VC)

·  ADVANCED VEHICLE SYS DIV (JB)

·  BODY ELECT, OCCUPANT SAFETY (JD

·  SMARTMOS PROD TECH CTR (JS

·  DRIVER INFORMATION DIVISION (JI)

·  NETWORK & COMM SYS DIV (NB)


ADDITIONAL RELIABILITY DATA: None
REFERENCE: Contact Sales Office ()


SAMPLES: Contact Local Sales Office
REFERENCE: Contact Sales Office ()

Contact your local Motorola Sales Office.


For any questions concerning this notification:
REFERENCE: Contact Sales Office (BRIAN THOMSON)

DISCLAIMER
      DISCLAIMER:
     
      MOTOROLA WILL CONSIDER THIS CHANGE APPROVED UNLESS SPECIFIC
      CONDITIONS OF ACCEPTANCE ARE PROVIDED IN WRITING WITHIN 30 DAYS OF
      RECEIPT OF THIS NOTICE. TO DO SO, CONTACT YOUR LOCAL MOTOROLA SALES
      OFFICE.

DO NOT REPLY TO THIS MESSAGE.
GPCN FORMAT:           CUSTOMER

DESCRIPTION AND PURPOSE

      Further to PCN 8680, Motorola SPS would like to announce the
      successful correlation of the elimination of ambient test from
      the final test flow on the MC9S12Dx64 (2L86D).
     
      The evaluation process has been successfully completed according to
      Motorola specification 12MRE10539D, with all criteria met. The
      results of this exercise are summarized below.
     
      Qualification was carried out successfuly for MC9S12Dx64 with a
      total of 0 fails from 76,109 tested units representing 28 separate
      wafer lots processed in the same fabrication facility.
     
      The test flow will be changed to remove 100 percent ambient test.
     
      The production final Test Flow will now be 100 percent Burn-In, 100
      percent Hot Test, 100 percent Cold Test and QA Gate Sampling Plan.
     
      REFERENCE PREVIOUS PCN NUMBERS:
      8680 - Ambient Test Elim'n on MC9S12D64

QUALIFICATION PLAN

      1. Analyze failures from a minimum of 46,052 parts from at least 12
      wafer lots taken from MC9S12D64FU and MC9S12D64PV.
      2. Ensure all ambient test failures from existing test flow are
      captured as failures in ambient eliminated test flow.
      3. Eliminate ambient test on MC9S12D64FU and MC9S12D64PV after
      customer notification.

RELIABILITY DATA SUMMARY

      N/A

ELECTRICAL CHARACTERISTIC SUMMARY

      MC9S12Dx64 ambient test elimination was validated using 76,109
      devices taken from 28 wafer lots.
     
      Validation product consisted of a representative mixture of both
      80QFP and 112LQFP.
     
      100 percent correlation of ambient fails was achieved to the revised
      test flow.

CHANGED PART IDENTIFICATION

      N/A


RELATED NOTIFICATIONS:

AMBIENT TEST ELIMN ON MC9S12D64

AFFECTED DEVICE LIST

PART

BV9S12D32CFU

KMC9S12A64CFU

KMC9S12A64CPV

KMC9S12D64CFU

KMC9S12D64CPV

KMC9S12D64MFU

KMC9S12D64MPV

KMC9S12D64VFU

KMC9S12D64VPV

KMC9S12DJ64CFU

KMC9S12DJ64CPV

KMC9S12DJ64MFU

KMC9S12DJ64MPV

KMC9S12DJ64VFU

KMC9S12DJ64VPV

MC9S12A64CFU

MC9S12A64CPV

MC9S12D64CFU

MC9S12D64CPV

MC9S12D64MFU

MC9S12D64MPV

MC9S12D64VFU

MC9S12D64VPV

MC9S12DJ64CFU

MC9S12DJ64CPV

MC9S12DJ64MFU

MC9S12DJ64MPV

MC9S12DJ64VFU

MC9S12DJ64VPV

MC9SD64CFUR2

MC9SD64CPVR2

MC9SD64MFUR2

MC9SD64MPVR2

MC9SD64VFUR2

MC9SD64VPVR2

MC9SDJ64CFUR2

MC9SDJ64CPVR2

MC9SDJ64MFUR2

MC9SDJ64MPVR2

MC9SDJ64VFUR2

MC9SDJ64VPVR2

PC9S12D64CFU25

PC9S12D64CPV25

PC9S12D64MFU25

PC9S12D64MPV25

PC9S12D64VFU25

PC9S12D64VPV25

PC9S12DJ64ECPV25

PC9S12DJ64EMPV25

PC9S12DJ64EVPV25

PC9S12DJ64GMFU

PC9S12DJ64GMPV

PC9S12DJ64MFU25

SC511348CFU

SC511348CFUR2

SC511348MFU

SC511348MFUR2

SC511348VFU

SC511348VFUR2

SC515516CFU

SC515516CFUR2

SC515516MFU

SC515516MFUR2

SC515516VFU

SC515516VFUR2

SC515518CPV

SC515518CPVR2

SC515518MPV

SC515518MPVR2

SC515518VPV

SC515518VPVR2

SC515520CFU

SC515520CFUR2

SC515529CPV

SC515532CPV

SC515533CFU