// BATTERY SUPPLEMENT MODE
//-----------------------------------------------------------------------------
CHARGER_EN:OFF          // Turn OFF charger
VBUS_ILIMIT_SET:250     // Set VBUS current limit to 250mA
DELAY:100:              // Wait 100ms
ELOAD_ISET:500          // System Load = 500mA
DELAY:100:              // Wait 100ms 
SYS_POLLING:ON          // Active Metering Enabled
PAUSE:
//-----------------------------------------------------------------------------
ELOAD_ISET:0            // System Load = 0mA
DELAY:100:              // Wait 100ms
CHARGER_EN:OFF          // Turn OFF charger
DELAY:100:              // Wait 100ms
SYS_POLLING:OFF         // Active Metering Disabled