Select a section:
Characteristic | Symbol | 250 MHz |
900 MHz |
4000 MHz |
Unit |
Insertion Loss | IL | –0.6 | –0.7 | –1.3 | dB |
Attenuation Accuracy (Worst Case State) | — | +0.1, –0.1 | +0.1, 0 | +0.1, –0.1 | dB |
Third Order Intercept Input Point(2) | IIP3 | 47 | 54 | 52 | dBm |
Power Input @ 1 dB Compression | P1dB | 30 | 35(3) | 35(3) | dBm |